Model | WBP-H60-V012 | ||||
Input | Voltage range | 180~264VDC (please refer to the derating curve) | |||
Input current | 0.3A/230VDC, | ||||
Frequency Range | 47~63Hz | ||||
Efficiency | ≥84% | ||||
PF | PF≥0.95/Vin=200~277Vac | ||||
leakage current | <0.7mA/240VAC | ||||
Inrush current | Low temperature start-up 80A/240VAC | ||||
Output | DC voltage | 12V | |||
Rated current | 5A | ||||
Output power | 60W | ||||
Ripple & noise | 500mVp-p | ||||
Rise up time | 50ms/230VAC Load 100% | ||||
Turn-on delay time | 30ms/230VAC Load 100% | ||||
Line regulation | ±1% | ||||
Load regulation | ±2% | ||||
Voltage tolerance | ±2% | ||||
Environment condictions | Range of working temperature | -40~70°C(refer to derating curve for details) | |||
Storage temperature | -40~85℃ 10%~95%RH Non-condensing | ||||
IP Grade | IP67 | ||||
Altitude | 5000mtrs (Altitude over 2000 meters, the load is derated by 1.5% for every 100 meters.) | ||||
EMC | Conducted electromagnetic disturbance (CE) | EN55015 | |||
Harmonic current | Compliance to IEC 61000-3-2 Class C(Load ≥50%) | ||||
Radiated electromagnetic disturbance (RE) | EN55015 | ||||
Radio frequency electromagnetic field immunity (RS) | IEC 61000-4-3 Level 2, IEC61547,refer to B | ||||
Conducted immunity (CS) |
IEC 61000-4-6 Level 2, IEC61547,refer to B | ||||
Electrical fast transient burst (EFT) | IEC 61000-4-4 Level 2,IEC61547,refer to B | ||||
Surge | IEC 61000-4-5 Differential mode ±2kV Common mode±4kV Refer to B |
||||
Safety regulations | Hi-pot | I/P-O/P | 3750Vac 60S,current≤10mA | No arcing,no breakdown | |
I/P-FG | 1750Vac 60S,current≤10mA | ||||
O/P-FG | 500Vac 60S,current≤10mA | ||||
Insulation Resistance | I/P-O/P | ≧10MΩ @ 500VDC | Relative Hunimidy:90%, DC Voltage:500V | ||
I/P-FG | ≧10MΩ@ 500VDC | ||||
O/P-FG | ≧10MΩ@ 500VDC | ||||
Safety Standard | Compliance to IEC/EN61347-1、EN61347-2-13、 GB19510,UL1310 |
||||
Protection | Over Voltage protection | 14~16V | |||
Over current protection | 7-10A, Hiccup mode, auto-recovery after fault condition is removed | ||||
Over temperature protection | 70-80 ℃ | ||||
Short circuit protection | Hiccup mode, auto-recovery after fault condition is removed | ||||
Reliability | MTBF | 25°C environmen:150000Hrs,MIL-217 Method | |||
Others | Dimension | 166*50*31mm(L*W*H) | |||
Packaging | 0.29Kg/Piece,36Piece/Box,10.9KG/box | ||||
Cooling method | Ventilation cooling √Air cooling | ||||
Extension method | Three-proofing lacquer Stamped Low temperature start-up(-40℃) Others |
||||
Note | *Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C. *In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected. * Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors. *The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility. |