Model | WBP-B600-024 | ||||
Input | Voltage range | 176~305VDC | |||
Max Input current | 4A/176VAC, | ||||
Frequency Range | 47~63Hz | ||||
PF | PF≥0.95/200~240Vac | ||||
leakage current | <0.7mA/240VAC | ||||
Inrush current | Low temperature start-up 60A/240VAC | ||||
Output | DC voltage | 24V | |||
Output Voltage Range Under Constant Current Area |
16~22.5 VDC | ||||
Rated current | 25A | ||||
Output power | 600W | ||||
Ripple & noise | 300mVp-p | ||||
Output Voltage Rise time | 200ms/200~240VAC | ||||
Turn-on delay time | 1s | ||||
Efficiency | ≥92%(Typ.93%) | ||||
Line regulation | ±1% | ||||
Load regulation | ±2% | ||||
Voltage tolerance | ±2% | ||||
Environment condictions | Range of working temperature | -40~70°C(refer to derating curve for details) | |||
Storage temperature | -40~85℃ 10%~95%RH Non-condensing | ||||
IP Grade | IP67 | ||||
Altitude | 5000mtrs (Altitude over 2000 meters, the load is derated by 1.5% for every 100 meters.) | ||||
EMC | Conducted electromagnetic disturbance (CE) | EN55015 | |||
Harmonic current | Compliance to IEC 61000-3-2 Class C(Load ≥50%) | ||||
Radiated electromagnetic disturbance (RE) | EN55015 | ||||
Radio frequency electromagnetic field immunity (RS) | IEC 61000-4-3 Level 2, IEC61547, Criterion B | ||||
Conducted immunity (CS) |
IEC 61000-4-6 Level 2, IEC61547,Criterion B | ||||
Electrical fast transient (EFT)/Burst | IEC 61000-4-4 Level 2,IEC61547,Criterion B | ||||
Surge | IEC 61000-4-5 Differential mode ±6kV Common mode±10kV Criterion B |
||||
Safety regulations | Hi-pot | I/P-O/P | 3750Vac 60S,current≤10mA | No arcing,no breakdown | |
I/P-FG | 1850Vac 60S,current≤10mA | ||||
O/P-FG | 500Vac 60S,current≤10mA | ||||
Insulation Resistance | I/P-O/P | ≧10MΩ @ 500VDC | 1 atm, Relative Hunimidy:90% | ||
I/P-FG | ≧10MΩ@ 500VDC | ||||
O/P-FG | ≧10MΩ@ 500VDC | ||||
Safety Standard | Compliance to IEC/EN61347-1、EN61347-2-13、 GB19510,UL1310 |
||||
Protection | Over Voltage protection | 30~35V | |||
Over temperature protection | 70-85 ℃ | ||||
Short circuit protection | Long time short-circuit protection without damage, recovers automatically after fault condition is removed. |
||||
Reliability | MTBF | 25°C environmen:150000Hrs,MIL-217 Method | |||
Others | Dimension | 274*138*48.5mm(L*W*H) | |||
Cooling method | √Ventilation cooling ◻️Air cooling | ||||
Extension method | ◻️Three-proofing lacquer ◻️Stamped ◻️Low temperature start-up(-40℃) ◻️Others |
||||
Note | *Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C. *In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected. * Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors. *The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility. |