Model | WBP-H240-V012 | WBP-H240-V024 | WBP-H240-V036 | WBP-H240-V048 | |
Input | Voltage range | 176~264VAC (please refer to the derating curve) | |||
Input current | 1.2A/230VAC, | ||||
Frequency Range | 47~63Hz | ||||
TYP(@230Vac) | 90% | 92% | 92% | 92.5% | |
PFC | PF≥0.95/230VAC | ||||
leakage current | <0.7mA/240VAC | ||||
Inrush current | Low temperature start-up60A /230VAC | ||||
Output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 20A | 10A | 6.6A | 5A | |
Output power | 240W | 240W | 237.6W | 240W | |
Voltage Adj. Range | |||||
Ripple & noise | 300mVp-p | 300mVp-p | 360mVp-p | 500mVp-p | |
Rise up time | 1000ms,50ms/230VDC Load100% | ||||
Switch on deday time | 50ms/230VAC,Load100% | ||||
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulation | ±3% | ±2% | ±1.5% | ±1.5% | |
Voltage tolerance | ±3.0% | ±2.0% | ±1.5% | ±1.0% | |
Environment condictions | Range of working temperature | -40~70°C 20%~95%RH non-condensing (refer to derating curve for details) | |||
Storage temperature | -40~80℃ 10%~95%RH Non-condensing | ||||
Vibration | Frequency range 10 ~ 500Hz, acceleration 2G, each sweep cycle of 10min, along the X, Y, Z axis for 6 sweep cycles | ||||
Impact | Acceleration 20G, duration 11ms, 3 shocks each along the X, Y, Z axes | ||||
Altitude | 5000mtrs (more than 2000m, for every 100m increase, the ambient temperature is reduced by 0.6 °C) | ||||
EMC | EMC emission | Design Reference:EN55015; EN61000-3-3; GB17743, GB17625.1 | |||
Harmonic current | EN61000-3-2 Class C (@load≧60%) | ||||
EMC immunity | Design Reference:EN61000-4-2,3,4,5,6,8,11; EN61547; Surge Immunity: Line-to-Wire 4kV, Line-to-Ground 6kV Criterion B | ||||
Safety regulations | Safety specifications | Design Reference:GB19510.1,GB19510.14;IEC/EN61347-1、EN61347-2-13; | |||
Electrical Strength |
Input--Output I/P-O/P: 3.75Vac; Input --- Enclosure I/P-CASE: 2kVac; Output --- Enclosure O/P-CASE: 0.5kVac Each test time is: 1min | ||||
Insulation resistance | I/P-O/P:≥50M ohms;I/P-Case:≥50M ohms;O/P-Case:≥50M ohms | ||||
Protection |
Over Voltage protection | 14~16V | 26~28V | 39~50V | 51~63V |
Shutdown output, self-recovering |
|||||
Over load protection | 110~165% off output, hiccup mode | ||||
Over temperature protection | Turns off the output and recovers when the temperature drops | ||||
Short circuit protection | The power supply shuts down after the output is shorted, and the short circuit is removed and self-recovering | ||||
Reliability | MTBF | 25°C environmen:150000Hrs,MIL-217 Method | |||
Others | Dimension | 230*63*40mm(L*W*H) | |||
Packaging | 1.07Kg/Piece,12Piece/Box,13.5KG/box | ||||
Cooling method | √Ventilation cooling Air cooling | ||||
Extension method | Three-proofing lacquer Stamped √Low temperature start-up(-40℃) Others | ||||
Note | *Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C. *In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected. * Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors. *The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility. |
+8675523208269
jack_xu@leadpowers.com
https://www.leadpowers.com
+8675523208269
Unit 401-403,Block 5B,Skyworth Innovation Valley,Tangtou 1st Road ,Shiyan Street,Bao'an District, Shenzhen,China