Model | WBP-H200-V012 | ||||
Input | Rated Input Voltage | 200-240Vac | |||
Input Voltage Range | 176~264Vac | ||||
Frequency Range | 47~63(Typ. 50/60)HZ | ||||
Max. Input Current | ≤2.5A | ||||
Inrush Current | ≤80A | ||||
PF | ≥0.95 | ||||
THD | ≤18% | ||||
Output | Rated output voltage | 12V | |||
Rated Output Current | 15A | ||||
Max. Output Power | 180W | ||||
Efficiency | ≥87%(Typ. 89%) | ||||
Output Ripple & Noise | ≤300mVp-p | ||||
Line regulation | ±1% | ||||
Load regulation | ±2% | ||||
Voltage tolerance | ≤±2% | ||||
Environment Condition | Range of working temperature | -40~ +70(Typ. 25)℃ | |||
Storage temperature | -45~+85(Typ. 25)℃ | ||||
Relative Humidity | 10~95% | ||||
Cooling Method | Air Convection | ||||
Altitude | 0~5000m | ||||
Protection Rating | IP67 | ||||
Max. Case Temperature | 90℃ | ||||
Safety | Leakage Current | ≤0.7mA | 240Vac/60Hz | ||
Hi-pot | Input To Output | 3750Vac 60S,current≤10mA | No arc, no breakdown |
||
Input To FG | 1750Vac 60S,current≤10mA | ||||
Output To FG | 500Vac 60S,current≤10mA | ||||
Insulation resistance | Input To Output | ≥10MΩ@ 500Vdc | 90%RH, 500VDC | ||
Input To FG | ≥10MΩ@ 500Vdc | ||||
Output To FG | ≥10MΩ@ 500Vdc | ||||
Safety Standard | Compliance to IEC/EN61347-1、EN61347-2-13、 GB19510,UL1310,CCC,CB+CE(TUV) Passed |
||||
EMC | Harmonic Current | Compliance to IEC 61000-3-2 Class C (@Load≥50%) |
|||
Conducted Emissions (CE) | EN55015 | ||||
Radiated Emissions (RE) | EN55015 | ||||
Radiated, Radio-Frequency, Electromagnetic Field Immunity (RS) | IEC 61000-4-3 Level 2, IEC61547, Criterion B | ||||
Conducted Immunity (CS) | IEC 61000-4-6 Level 2, IEC61547, Criterion B | ||||
Electrical Fast Transient (EFT)/Burst | IEC 61000-4-4 Level 2, IEC61547, Criterion B | ||||
Surge | IEC 61000-4-5 Differential Mode: ±2kV Common Mode: ±4kV Criterion B |
||||
Protection | Over voltge protection | ≤16V | |||
Over current protection | 20~25A | ||||
Over-temperature protection | 70-80℃ | Ambient Temperature, full load | |||
Output short-circuit protection | Yes | ||||
Reliability | MTBF | 25℃:100000Hrs,MIL-217 Method | |||
Others | Dimension | 217*63*40(L*W*H) | |||
Cooling method | √Ventilation Cooling ⬜air cooling | ||||
Extension method | ⬜Three-proofing lacquer ⬜Stamped ⬜Low temperature start-up(-40℃)⬜Others |
||||
Note | *Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C. *In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected. * Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors. *The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility. |
+8675523208269
jack_xu@leadpowers.com
https://www.leadpowers.com
+8675523208269
Unit 401-403,Block 5B,Skyworth Innovation Valley,Tangtou 1st Road ,Shiyan Street,Bao'an District, Shenzhen,China