1 |
|
Input |
||
No. |
Item |
Technical Requirements |
Unit |
Note |
1.1 |
Rated Input Voltage |
200~240 |
Vac |
|
1.2 |
Input Voltage Range |
176~264 |
Vac |
Refer to derating curve |
1.3 |
Rated Frequency |
47~63(Typ. 50/60) |
Hz |
|
1.4 |
Max. Input Current |
0.8 |
A |
Vin=190Vac, rated load |
1.5 |
Inrush Current |
≤50 |
A |
240Vac input, rated load, 25℃ |
2 |
|
Output |
||
No. |
Item |
Technical Requirements |
Unit |
Note |
2.1 |
Rated output voltage |
12 |
Vdc |
|
2.2 |
Rated output current |
5 |
A |
|
2.3 |
Max Output power |
60 |
W |
Refer to derating curve |
2.4 |
Efficiency |
≥85% |
- |
230Vac input, rated load, 25℃ |
2.5 |
Line regulation |
±1% |
|
|
2.6 |
Load regulation |
±2% |
|
|
2.7 |
Voltage tolerance |
±2% |
|
|
2.8 |
Ripple & Noise |
≤200 |
mVp-p |
25℃,230VInput, Rated Load, Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
2.9 |
Dynamic Response Overshoot |
≤5 |
% |
25%~50%~25 and 50%~75%~50% load dynamic, the half-wave period is 4mS, the current change slope is 0.1A/uS |
2.10 |
Turn-on Delay Time |
≤3 |
s |
200~240Vac input, rated load |
2.11 |
Shutdown hold time |
- |
ms |
Rated input voltage, rated load |
2.12 |
Turn-on/off Overshoot |
≤±10% |
|
|
3 |
|
Protection |
||
No. |
Item |
Technical Requirements |
Unit |
Note |
3.1 |
Current limiting protection |
6~8 |
A |
Hiccup model, recovers automatically after fault condition is removed |
3.2 |
Short Circuit Protection |
Long time short-circuit protection without damage, recovers automatically after fault condition is removed. |
+8675523208269
jack_xu@leadpowers.com
https://www.leadpowers.com
+8675523208269
Unit 401-403,Block 5B,Skyworth Innovation Valley,Tangtou 1st Road ,Shiyan Street,Bao'an District, Shenzhen,China