1 |
Input |
|||
No. |
Item |
Technical Requirements |
Unit |
Note |
1.1 |
Rated Input Voltage |
200~240 |
Vac |
|
1.2 |
Input Voltage Range |
176~264 |
Vac |
Refer to derating curve |
1.3 |
Frequency Range |
47~63 |
Hz |
|
1.4 |
Max. Input Current |
2.5 |
A |
Vin=190Vac, rated load |
1.5 |
Inrush Current |
≤80 |
A |
240Vac input, 25℃, cold start |
2 |
Output |
|||
No. |
Item |
Technical Requirements |
Unit |
Note |
2.1 |
Rated output voltage |
12 |
Vdc |
|
2.2 |
Rated output current |
16.7 |
A |
|
2.3 |
Max Output power |
200.4 |
W |
Refer to derating curve |
2.4 |
Efficiency |
≥87% |
- |
Vin=230Vac,rated load, 25℃ |
2.5 |
Line regulation |
±1% |
|
|
2.6 |
Load regulation |
±2% |
|
|
2.7 |
Voltage tolerance |
±2% |
|
|
2.8 |
Ripple & Noise |
≤300 |
mVp-p |
25℃, rated input, rated load, bandwidth of 20MHz, connected a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel to the output terminals. |
2.9 |
Dynamic Response Overshoot |
≤5 |
% |
5%~50%~25%, 50%~75%~50 load dynamics, half-wave period is 4mS, current change slope is 0.1A/uS |
2.10 |
Turn-on Delay Time |
≤3 |
s |
200~240Vac input, rated load |
2.11 |
Output Voltage Rise Time |
- |
ms |
Rated input voltage, rated load, 25℃ |
2.12 |
Turn-on/off Overshoot |
≤±10% |
|
|
3 |
Protection |
|||
No. |
Item |
Technical Requirements |
Unit |
Note |
3.1 |
Input Under Voltage Protection |
130~150 |
Vac |
|
3.2 |
Input Under Voltage Recovery |
150~180 |
Vac |
|
3.3 |
Over Current Protection |
20~25 |
A |
Hiccup model, recovers automatically after fault condition is removed |
3.4 |
Short Circuit Protection |
Long time short-circuit protection without damage, recovers automatically after fault condition is removed. |