Model |
RAN-H150-V012 |
RAN-H150-V024 |
RAN-H150-V036 |
RAN-H150-V048 |
Input |
Voltage range |
180~264Vac |
176~264VAC |
Input Current |
230VAC/1.5A |
Efficiency |
≥84% |
≥85% |
≥84% |
≥84% |
Frequency Range |
47~63HZ |
Leakage Current |
<1mA/240VAC |
Inrush Current |
≤80A, 230Vac input, 25℃ Cold start |
50A/230VAC,Cold start |
Output |
Rated output voltage |
12V |
24V |
36V |
48V |
Rated current |
12.5A |
6.5A |
4.2A |
3.12A |
Voltage power |
150W |
156W |
151.2W |
150W |
Voltage Adj. Range |
±5% |
±5% |
±5% |
±5% |
Output Ripple & Noise |
300mVp-p |
300mVp-p |
120mVp-p |
120mVp-p |
Rise up time |
2000ms,50ms/230VAC, fully loaded 100% |
Swich on delay time |
20ms/230VAC, fully loaded100% |
Line regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load regulation |
±1.5% |
±0.5% |
±1.5% |
±1.5% |
Voltage tolerance |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Environment Condition |
Range of working temperature |
-20~60℃ 20%~95%RH, no condensation(Refer to derating curving) |
-20~70℃ 20%~95%RH, no condensation(Refer to derating curving) |
Storage temperature |
-30~80℃ 20%~95%RH, no condensation |
-40~80℃ 10%~95%RH, no condensation |
Vibration |
Frequency range 10 ~ 500Hz, acceleration 2G, each sweep cycle of 10min, along the X, Y, Z axis for 6 sweep cycles |
Impact |
Acceleration 20G, duration 11ms, 3 shocks each along the X, Y, Z axes |
Altitude |
2000mtrs(Above 2000m, the ambient temperature decreases by 0.6℃ for every 100m rise) |
EMC |
Electromagnetic resistance |
Design Reference:EN55024;EN61000-4-2,3,4,5,6,8,11 |
Harmonic current |
Design Reference:GB17625.1;EN61000-3-2,-3 limit requirements |
EMC specification |
Design Reference:EN55022 |
Safety regulations |
Safety Specifications |
Design Reference:GB4943/UL1012 |
Dielectrical Strength |
I/P-O/P:3.0Kvac/10mA/1min; I/P-FG:1.5Kvac/10mA/1min; O/P-FG:0.5Kvac/10mA/1min |
Input-- I/P-O/P:1.5Kvac/5mA/1min; I/P-CASE:1.5Kvac/5mA/1min; O/P-CASE:0.5Kvac/5mA/1min |
Insulation resistance |
I/P-O/P:10M ohms@500Vdc; I/P-FG:10M ohms@500Vdc; O/P-FG:10M ohms@500Vdc |
I/P-O/P:50M ohms; I/P-Case:50M ohms; O/P-Case:50M ohms |
Protection |
Over voltge protection |
/ |
/ |
/ |
/ |
/ |
Overload protection |
110~165% rated, Hiccup mode, after eliminating overload can automatically return to normal work |
Over-temperature protection |
/ |
Output short-circuit protection |
Recovers automatically after fault condition is removed. |
Reliability |
MTBF |
25℃:100000Hrs,MIL-217 Method |
Others |
Dimension |
226*102*50(L*W*H) |
Packaging |
0.29Kg/piece,24 pieces/box,15KG/box |
Cooling method |
√Ventilation Cooling ◻️air cooling |
Extension method |
◻️Three-proofing lacquer ◻️Stamped ◻️Low temperature start-up(-40℃)◻️Others |
Note |
*Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C. *In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected. * Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors. *The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility. |