Products
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
  • RAP-K400 Series Semi Glue Filling Power Supply
RAP-K400 Series Semi Glue Filling Power Supply
  • High efficiency, long life and high reliability
  • Voltage input range 90 to 264VAC
  • -30~+60°C operating temperature (specifically check the derating curve)
  • All use 105°C long-life electrolytic capacitors
  • Short-circuit/overload/overvoltage protection function
  • Free cooling
  • 100% full load aging
  • 3-year warranty
Model RAP-K400-V012P
Input Voltage range 90~264VDC
Max Input current 5A/176VAC,
Frequency Range  47~63Hz
PF  PF≥0.95/100~240Vac
Inrush current ≤90A
Output DC voltage 12V
Output Voltage Range
Under Constant Current
Area
10.8~13.2 VDC
Rated current 15A 90~200Vac input
27A 200~264Vac input
Output power 360W
Efficiency ≥88%(Typ.90%)
Ripple & noise 150mVp-p
Output Voltage Rise time 100ms
Dynamic Response Overshoot 5%
Dynamic Response Recovery Time 300μs
Turn-on delay time 3s
Line regulation ±1%
Load regulation 2%
Voltage tolerance ≤±4%
Environment condictions Range of working temperature -30~60°C(refer to derating curve for details)
Storage temperature -40~80℃ 5%~95%RH Non-condensing
Atmosphere Pressure 70~106Kpa
Altitude 5000mtrs (Altitude over 2000 meters, the load is derated by 1.5% for every 100 meters.)
EMC& Safety Dielectric Strength Input To Output 3000Vac/10mA/1min No arc, no breakdown
Input To FG 1500Vac/10mA/1min
Output To FG 500Vac/10mA/
1min
Insulation Resistance Input To Output ≥10MΩ@ 500Vdc 90%RH, 1 atm
Input To FG ≥10MΩ@ 500Vdc
Output To FG ≥10MΩ@ 500Vdc
Leakage Current Input To FG ≤3.5mA 240Vac/60Hz
Input To Output ≤0.7mA
Safety Standards he design conforms to UL60950, IEC/EN60950, GB4943.1-2011
standard requirements
  EMI EN55015
  EMS En61000-4-2,3,4,5,6,8,11, EN55024 Standard for
Light industry Class A (surge 4 kV) criteria B
Protection Over Voltage protection 13.8~16.2V
current-limiting protection 35~43A
Short circuit protection It can be short circuited for a long time without damage. After the short
circuit fault is removed, restarting the power supply is needed.
Reliability MTBF 25°C environmen:150000Hrs,MIL-217 Method
Others Dimension  235*115*42mm(L*W*H)
Cooling method √Ventilation cooling   Air cooling
Extension method Three-proofing lacquer Stamped 
Low temperature start-up(-40℃) 
Others
Note *Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, 25°C.
*In order to extend the service life, it is recommended to leave an additional 30% margin when configuring the load. For example, if the device requires 100W of power, the power supply of not less than 130W is selected.
* Switching power supply ripple test method: test on the power supply output terminal with a 20MHz oscilloscope, the ground length of the oscilloscope probe is not more than 12mm, and the probe input is paralleled with 47uF electrolytic capacitors and 0.1uF high frequency capacitors.
*The power supply is part of the equipment system components, and all EMC tests need to be confirmed in conjunction with the end equipment for electromagnetic compatibility.
Inquiry

+8675523208269

jack_xu@leadpowers.com

https://www.leadpowers.com

+8675523208269

Unit 401-403,Block 5B,Skyworth Innovation Valley,Tangtou 1st Road ,Shiyan Street,Bao'an District, Shenzhen,China

CONTACT US
  • Name*

  • E-Mail*

  • Write Your Message*

  • Code*

  • SEND